Comparative Analysis between Mineral Oil and Vegetable Oil used as Dielectrics and Refrigerants for Power Transformers
Análisis Comparativo entre el Aceite Mineral y el Aceite Vegetal Utilizados como Dieléctricos y Refrigerantes para Transformadores de Potencia
How to Cite
Download Citation
Show authors biography
Similar Articles
- Selene Peñafiel, Patricia Otero, Fabián Pérez, Diagnosis of the State of Distribution Transformers Through the Frequency Response Analysis Test , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Carlos Molina, Vladimir Bonilla, Application of CRISP-DM Methodology in the Analysis of Dissolved Gases in Dielectric oil of Electrical Transformers in the Ecuadorian Electrical Sector , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Armando Freire, Fernando Arias, Héctor Mullo, Jhonny Casa, Implementation of Remote Control for the Opening and Closing of Reactive Compensation to the 13,8 kV Feeder of the Electrical Substation of Novacero S.A. by means of an ADVC-IOEX Card , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Kleber Zhañay, Cristian Leiva, Erika Pilataxi, William Quitiaquez, Wear - Sediment Quantity Correlation Model for Preventive Maintenance Scheduling of a Hydroelectric Power Plant , Revista Técnica "energía": Vol. 21 No. 2 (2025): Revista Técnica "energía", Edición No. 21, ISSUE II
- Alex Mullo, José Reinoso, Marlon Chamba, Carlos Lozada, Analysis and Characterization of Power Quality using Data Mining , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- Andrés Pereira, Roberth Saraguro, Carlos Quinatoa, Evaluation of Active Power Losses in the Electrical System of the Empresa Eléctrica Quito (EEQ) Applying an Optimization Algorithm , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Paulo Castro, Jaime Cepeda, Impact Analysis of Non-Dispatchable Renewable Energies Penetration in Power System Operational Security , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- Wilson Vásquez, Power Factor Assessment in Users with Power Generation Equipment for Self-Consumption , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Julio Lascano, Luis Chiza, Roberth Saraguro, Carlos Quinatoa, Jessy Tapia, Demand Estimation for an Electric Vehicles Charging Station Through the Application of Probabilistic Methods , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Wilson Sánchez, Diego Echeverría, Santiago Chamba, Andrés Jacho, Carlos Lozada, Economic Energy Dispatch of the Micro-Grid in the Galapagos Islands Using the Simsee Platform , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
You may also start an advanced similarity search for this article.
The objective of this investigation is to evaluate the properties of vegetable oil and mineral oil used as dielectrics and refrigerants in power transformers, equipment that is used on the oil fields exploitation. Based on the ASTM D1524 standard, a visual test was carried out with five samples of each oil, obtaining average values of 1,15 and 0,6 for vegetable oil and mineral oil, respectively. The obtained results showed that vegetable oil keeps its properties for a long time, which extends the equipment's useful life. For the dielectric strength test, according to the ASTM D1816 test, five measurements were taken for the vegetable oil, obtaining as average values 32,9, 29,6, 31,1, 30,7, 32,6; meanwhile, for the mineral oil, the average results of the five measurements were 31,2, 28,5, 29,6, 28,9, 30. It demonstrated that the vegetable oil is better due to it has higher dielectric strength.
Article visits 2049 | PDF visits 1073