Co-simulation between PowerFactory and Matlab/Simulink for the simulation of an HVDC link integrated to the 39-bus system
Co-simulación entre PowerFactory y Matlab/Simulink para la simulación de un enlace HVDC integrado al sistema de 39 barras
How to Cite
Download Citation
Show authors biography
Similar Articles
- Joffre Constante, Lesly Ochoa, Brayan Caiza, Walter Rueda, Omar Chuquitarco, Parametric Identification of the Oscillatory Component Load Model Using Synchrophasor Measurements and Optimization Techniques , Revista Técnica "energía": Vol. 22 No. 2 (2026): Revista Técnica "energía", Edición No. 22 ISSUE II
- Joffre Constante, Robert Quinga, Klever Tigasi, Mauricio Mullo, Estimation of Exponential Recovery Load Model Parameters Using Synchrophasor Measurements , Revista Técnica "energía": Vol. 22 No. 2 (2026): Revista Técnica "energía", Edición No. 22 ISSUE II
- Joffre Constante, Henry Laica, Kevin Tituaña, Jessica Castillo, Filtering and Smoothing Techniques Assessment at the ZIP Load Model Parametric Estimation with Ambient PMU Data , Revista Técnica "energía": Vol. 22 No. 2 (2026): Revista Técnica "energía", Edición No. 22 ISSUE II
- Diego Paguay, Ricardo Lozada, Ariel Almeida, Carlos Lozada, Implementation of a Phasor Measurement Unit PMU Model in the Real Time Simulation Software for Electromagnetic Transients HYPERSIM , Revista Técnica "energía": Vol. 22 No. 2 (2026): Revista Técnica "energía", Edición No. 22 ISSUE II
- Jorge Leon, Graciela Colomé, Estefanía Tapia, Identification of Critical Generators in Transient Stability Problems , Revista Técnica "energía": Vol. 21 No. 2 (2025): Revista Técnica "energía", Edición No. 21, ISSUE II
- Paulo Castro, Jaime Cepeda, Impact Analysis of Non-Dispatchable Renewable Energies Penetration in Power System Operational Security , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- Gabriel Rivera, Mario Jinez, Lourdes Farinango, Dual-Scheme Modeling of Border Substations with Non-Conventional Sectionalizing Topologies in EMS via Normalized Residual Analysis of the State Estimator , Revista Técnica "energía": Vol. 23 No. 1 (2026): Revista Técnica "energía", Edición No. 23 ISSUE I
- Gabriel Rivera, Johnny Castellano, Óscar De Lima, Lourdes Farinango, Evaluation of Real-Time (EMS) and Off-Line Contingency Analysis Indexes for Static Security Assessment of the Ecuadorian Interconnected Power System , Revista Técnica "energía": Vol. 23 No. 1 (2026): Revista Técnica "energía", Edición No. 23 ISSUE I
- Gabriel Guañuna, Santiago Chamba, Nelson Granda, Jaime Cepeda, Diego Echeverría, Walter Vargas, Voltage Stability Margin Estimation Using Machine Learning Tools , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Alan Cuenca, Cristina Oña, Ismael Suquillo, Henry Miniguano, Design Methodology of Off-Grid PV Solar Powered Systems for Rural Areas in Ecuador , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
You may also start an advanced similarity search for this article.
Most read articles by the same author(s)
- Julio Lascano, Luis Chiza, Roberth Saraguro, Carlos Quinatoa, Jessy Tapia, Demand Estimation for an Electric Vehicles Charging Station Through the Application of Probabilistic Methods , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Luis Chiza , Jaime Cepeda, Transmission Corridor Stability Margin Prediction Applying Data Mining Criteria and Machine Learning Algorithms , Revista Técnica "energía": Vol. 18 No. 1 (2021): Revista Técnica "energía", Edición No. 18, ISSUE I
This paper focuses on the use of the co-simulation tool through the OPC Communication Protocol in its data acquisition (DA) variant, to integrate the Matlab/Simulink and PowerFactory models. Thus, a HVDC link is modeled in the Matlab environment and the 39-bus model is available in PowerFactory. Having this co-simulation environment operational, dynamic tests of the link operation can be performed, and consequently the performance of the controllers on each of the stations of the link can be determined.
Article visits 1653 | PDF visits 623
Downloads
[1] C. K. Kim, V. K. Sood, G. S. Jang, S. J. Lim y S. J. Lee, «HVDC Transmission: Power Conversion Applications in Power Systems.,» 2009.
[2] F. Wang, L. Bertling, T. Le, A. Mannikoff y A. Bergman, «An Overview Introduction of VSC-HVDC: State of art and Potential Applications in Electric Power Systems,» cigre. For power system expertise, vol. 21, 2011.
[3] M. Eremia, J. A. Jardini, G. Tang y L. Toma, «VSC-HVDC Transmission,» de Advanced Solutions in Power Systems: HVDC, FACTS, and Artificial Intelligence, Wiley-IEEE Press, 2016, pp. 125-267.
[4] W. Y. Sandino Sandoval y J. C. Rodríguez Romero, «Estudio y aplicación de un control de un enlace vsc-hvdc para el mejoramiento de la estabilidad de tensión de un sistema de potencia,» Bogotá, 2019.
[5] M. A. González Carranza , «Diagnótico del Potencia aporte de enlaces HVDC-VSC para otorgar flexibilidad y mejorar la respuesta dinámica en interconexiones regionales,» Santiago de Chile, 2018.