Coordination Study of Protections of the Subtransmission System of CNEL EP Sucumbíos due to the New Connection Point to the Interconnected National System (SNI)
Estudio de Coordinación de Protecciones del Sistema de Subtransmisión de CNEL EP Unidad de Negocios Sucumbíos ante un Nuevo Punto de Conexión al Sistema Nacional Interconectado (SNI)
How to Cite
Download Citation
Show authors biography
Similar Articles
- Wilson Sánchez, Diego Echeverría, Santiago Chamba, Andrés Jacho, Carlos Lozada, Economic Energy Dispatch of the Micro-Grid in the Galapagos Islands Using the Simsee Platform , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Armando Freire, Fernando Arias, Héctor Mullo, Jhonny Casa, Implementation of Remote Control for the Opening and Closing of Reactive Compensation to the 13,8 kV Feeder of the Electrical Substation of Novacero S.A. by means of an ADVC-IOEX Card , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Daniel Jiménez, Wilson Andino, Mauricio Soria, Fabián Pérez, Optimal Coordination of Inverse Time Overcurrent Relays using COA and GSA Heuristic Algorithms , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Rolando Noroña, Edgar Cajas, Carlos Lozada, Marlon Chamba, Transient Stability Analysis Using the Concept of Inertia and Data Mining , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- Nelson Granda, Karen Paguanquiza, System Frequency Response Models for the Ecuadorian Interconnected Power System , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Josua Oña, Luis Ruales, Analysis of over voltages due to atmospheric impulse in transmission systems with discontinuities, overhead transmission lines and insulated cables, using ATP , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- Flavio Villacrés, Alexis Torres, Marlon Chamba, Carlos Lozada, Adaptive Load Shedding Strategy for Power Systems Based on Linear Regression , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- José Castro, Paúl Soto, Ruth Reategui, Tuesman Castillo, Partitioning of an Electrical Distribution Systems Using K-Means and DBSCAN Clustering Algorithms , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Selene Peñafiel, Patricia Otero, Fabián Pérez, Diagnosis of the State of Distribution Transformers Through the Frequency Response Analysis Test , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Sasha Palacios, Ecuadorian National Interconnected System (SNI) Using the Equal Area Criterion and Synchrophasor Measurements , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
You may also start an advanced similarity search for this article.
Most read articles by the same author(s)
- F.I. Lozada , F.L. Quilumba, F.E. Pérez , Fault Detection and Classification in Transmission Lines Using Wavelet Transform and Support Vector Machines , Revista Técnica "energía": Vol. 14 No. 1 (2018): Revista Técnica "energía", Edición No. 14
Currently, Ecuador is experiencing changes in the energy matrix, which involves big projects in electricity area mainly in generation, transmission, subtransmission and distribution, particularly the entry into operation of the Coca Codo Sinclair generation plant and the creation of new supply points to the distribution companies.
In this context, the Corporación Eléctrica del Ecuador CELEC EP has built the substation named Jivino of TRANSELECTRIC, which constitutes for the electricity distribution company CNEL EP Sucumbíos, a new point of connection to the National Interconnected System (SNI).
This work carries out a study of protective device coordination in the CNEL EP Sucumbíos subtransmission system, due to the operation of the mentioned new connection point to the SNI, in order to determine the appropriate protection system and settings for the distribution company CNEL EP Sucumbíos. An analysis of the behavior of the two teleprotection schemes, which are PUTT (Permissive Under-reach Transfer Trip) and POTT (Permissive Over-reach Transfer Trip), for the protection of distance and its operation to direct faults and high impedance faults. Finally, the coordination of protections is verified by establishing different types of short-circuits.
Article visits 801 | PDF visits 621