Sensitivity analysis for the determination of characteristic curves of dead time vs transfer power applied to transmission lines
Análisis de sensibilidad para la determinación de curvas características de tiempos muertos vs potencia de transferencia aplicados a líneas de transmisión
How to Cite
Download Citation
Show authors biography
Similar Articles
- Jorge Leon, Graciela Colomé, Estefanía Tapia, Identification of Critical Generators in Transient Stability Problems , Revista Técnica "energía": Vol. 21 No. 2 (2025): Revista Técnica "energía", Edición No. 21, ISSUE II
- Julio Cardenas, Graciela Colomé, Estefania Tapia, Adaptive Generator Tripping to Improve Transient Stability in Systems with Renewable Generation Integration , Revista Técnica "energía": Vol. 22 No. 2 (2026): Revista Técnica "energía", Edición No. 22 ISSUE II
- Sasha Palacios, Ecuadorian National Interconnected System (SNI) Using the Equal Area Criterion and Synchrophasor Measurements , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- Gabriel Guañuna, Graciela Colomé, Estefanía Tapia, Short-Term Stability State Prediction in Power Systems with Renewable Generation Integration Using Deep Learning , Revista Técnica "energía": Vol. 22 No. 2 (2026): Revista Técnica "energía", Edición No. 22 ISSUE II
- Nelson Granda, Karen Paguanquiza, System Frequency Response Models for the Ecuadorian Interconnected Power System , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Gabriel Guañuna, Santiago Chamba, Nelson Granda, Jaime Cepeda, Diego Echeverría, Walter Vargas, Voltage Stability Margin Estimation Using Machine Learning Tools , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Flavio Villacrés, Alexis Torres, Marlon Chamba, Carlos Lozada, Adaptive Load Shedding Strategy for Power Systems Based on Linear Regression , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- Josua Oña, Luis Ruales, Analysis of over voltages due to atmospheric impulse in transmission systems with discontinuities, overhead transmission lines and insulated cables, using ATP , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- Rolando Noroña, Edgar Cajas, Carlos Lozada, Marlon Chamba, Transient Stability Analysis Using the Concept of Inertia and Data Mining , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- Diego Paguay, Ricardo Lozada, Ariel Almeida, Carlos Lozada, Implementation of a Phasor Measurement Unit PMU Model in the Real Time Simulation Software for Electromagnetic Transients HYPERSIM , Revista Técnica "energía": Vol. 22 No. 2 (2026): Revista Técnica "energía", Edición No. 22 ISSUE II
You may also start an advanced similarity search for this article.
For the transmission of large electric power blocks to large lengths, Extra High Voltage systems are a good alternative, where the elements that make up the transmission system must be designed in such a way that they offer high reliability and availability during their operation. In this context, it is necessary to perform a proper single-phase autoreclosure, determining the power transmission capacity and the reclosure dead time in the event of single-phase line-to-ground failure considering a single-phase opening and reclosing scheme and Transient Stability of the system. In this sense, this research proposes a methodology to determine characteristic curves corresponding to dead time vs active power of transfer that guarantee a maximum transfer of active power through the transmission lines, and transient stability due to failure, opening and single-phase reclosing events. These characteristic curves will make it possible to decide, from the point of view of transient stability, the most suitable value for adjusting the single-phase reclosing dead time and the dispatched power of the generation central.
Article visits 1739 | PDF visits 588