Modelación y Validación en ATP de los Cables Subterráneo y Submarino del Sistema de Subtransmisión Baltra - Santa Cruz
Modelación y Validación en ATP de los Cables Subterráneo y Submarino del Sistema de Subtransmisión Baltra - Santa Cruz
How to Cite
Download Citation
Show authors biography
Similar Articles
- Joffre Constante, Augusto Riofrío, Aharon De La Torre, Jaime Cepeda, Methodology for Steady-State and Dynamic Modelling of S.N.I in HYPERsim, Application in the Electromagnetic Transient Analysis for 500 kV Systems , Revista Técnica "energía": Vol. 16 No. 2 (2020): Revista Técnica "energía", Edición No. 16
- Josua Oña, Luis Ruales, Analysis of over voltages due to atmospheric impulse in transmission systems with discontinuities, overhead transmission lines and insulated cables, using ATP , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- Andrés Pereira, Roberth Saraguro, Carlos Quinatoa, Evaluation of Active Power Losses in the Electrical System of the Empresa Eléctrica Quito (EEQ) Applying an Optimization Algorithm , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Josue Ortiz, Jefferson Tayupanda, Carlos Quinatoa, Solution to the short-term hydrothermal dispatch problem through nonlinear programming applied to single and multi-node systems , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- Edison Novoa, Gabriel Salazar Yépez, Eliana Buitrón, Gabriel Salazar Pérez, Methodological Proposal for Targeting Electric Subsidy "Tarifa De La Dignidad" in Residential Users of the Electric Companies of Ecuador , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Wilson Sánchez, Diego Echeverría, Santiago Chamba, Andrés Jacho, Carlos Lozada, Economic Energy Dispatch of the Micro-Grid in the Galapagos Islands Using the Simsee Platform , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Carlos Lozada, David Panchi, Wilson Sánchez, Andrés Jacho, Linear Regression for the Identification of the Maximum Power Point in Hybrid Microgrids Implemented in HYPERSIM , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- Daniel Orbe, Luis Salazar, Paúl Vásquez, Estimation and Sensitivity Analysis of Electric Buses Energy Consumption through Microscopic Simulations on Public Transport Lines , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- Daniels Mendoza, Isai Nina, Edwin Cuadros, Analysis of a Geothermal Pilot Plant with a Medium-Enthalpy Binary Cycle, Ubinas, Moquegua , Revista Técnica "energía": Vol. 21 No. 2 (2025): Revista Técnica "energía", Edición No. 21, ISSUE II
- Wilson Pavón, Sandra Gualotuña, Droop control strategy for an isolated micro grid with distributed generation coupled to improve voltage stability , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
You may also start an advanced similarity search for this article.
In this paper, the criteria used for modeling and validation of underground and submarine tripolar cables of Baltra Santa Cruz power system are presented. To model cables with Cable Parameters routines, inserted in EMTP type programs, pretreatment of design data and construction of the cables was performed. Also, to analyze the underground cable was necessary to add to your model a fictional armor so that can be modeled as type “Pipe”. The study of electromagnetic transients line energization was performed using the ATP software, but because the state of the art indicates limitations on cable and not symmetrical aerial transmission lines when Bergeron or JMarti models, incorporated into ATP, an analysis was carried out that allowed to determine to what extent is valid the JMarti model by comparing its transient response voltage with those offered by the WideBand model, built in EMTP-RV, which is considered the most accurate line and cable model today. For this purpose, the JMarti models for submarine and underground cable were adjusted with a frequency value according to suggested by CIGRÉ. The results indicate that the JMarti model provides acceptable voltage signals only to the energized conductor, while for other voltages induced in phase conductors and screens and metal armatures model fails.
Article visits 1460 | PDF visits 784