Numerical Study Using CFD of the Cooling Process with Heat Exchangers in Computer Systems
Estudio Numérico Mediante CFD del Proceso de Enfriamiento con Intercambiadores de Calor en Sistemas Computacionales
How to Cite
Download Citation
Show authors biography
Similar Articles
- Fernando Toapanta, Melany Oña, Numerical Study with CFD of the Refrigeration in a Vehicle Cabin with two Refrigerants R32 and R600a , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- William Quitiaquez, Andrés Argüello, Isaac Simbaña, Patricio Quitiaquez, Evaluation of the gasoline engines behavior by the air flow simulation through the throttle body , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Daniels Mendoza, Isai Nina, Edwin Cuadros, Analysis of a Geothermal Pilot Plant with a Medium-Enthalpy Binary Cycle, Ubinas, Moquegua , Revista Técnica "energía": Vol. 21 No. 2 (2025): Revista Técnica "energía", Edición No. 21, ISSUE II
- Isaac Simbaña, William Quitiaquez, Patricio Cabezas, Patricio Quitiaquez, Comparative study of the efficiency of rectangular and triangular flat plate solar collectors through finite element method , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- Isaac Simbaña, Sarai Mena, Silvana Chasipanta, EEnergy Efficiency Analysis of an Electric Furnace through the Implementation of a Forced Convection Fan , Revista Técnica "energía": Vol. 22 No. 1 (2025): Revista Técnica "energía", Edición No. 22, ISSUE I
- Alex Rivera, William Quitiaquez, Isaac Simbaña, Patricio Quitiaquez, Study of Steam Generation and Distribution in a Hospital to Improve Energy Efficiency Using Thermography, Ultrasound, and Gas Analyzer , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- Karina Tituana, Vanessa Guillén, Analysis of the Thermal Comfort Perception in Residential Buildings in Loja City based on Ecuadorian Energy Efficiency Standard , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
- William Quitiaquez, Hugo Meneses, Patricio Quitiaquez, Isaac Simbaña, Regeneration of Deteriorated Internal Combustion Engine Components used in Thermal Power Plants , Revista Técnica "energía": Vol. 21 No. 2 (2025): Revista Técnica "energía", Edición No. 21, ISSUE II
- Kleber Zhañay, Cristian Leiva, Erika Pilataxi, William Quitiaquez, Wear - Sediment Quantity Correlation Model for Preventive Maintenance Scheduling of a Hydroelectric Power Plant , Revista Técnica "energía": Vol. 21 No. 2 (2025): Revista Técnica "energía", Edición No. 21, ISSUE II
- Graciela Colomé, Omar Ramos, Diego Echeverría, Identification Methodology of Oscillatory Modes in PMU Measurement Ambient Type Data , Revista Técnica "energía": Vol. 21 No. 1 (2024): Revista Técnica "energía", Edición No. 21, ISSUE I
You may also start an advanced similarity search for this article.
Most read articles by the same author(s)
- William Quitiaquez, Isaac Simbaña, Robinson Caizatoa, César Isaza, César Nieto, Patricio Quitiaquez, Fernando Toapanta, Analysis of the thermodynamic performance of a solar-assisted heat pump using a condenser with recirculation , Revista Técnica "energía": Vol. 16 No. 2 (2020): Revista Técnica "energía", Edición No. 16
- Carlos Maigua, William Quitiaquez, Isaac Simbaña, Patricio Quitiaquez, Fernando Toapanta, César Isaza, Diseño de un Sistema de Monitoreo de Vibraciones Mecánicas en Generadores Hidroeléctricos de Media Potencia , Revista Técnica "energía": Vol. 17 No. 1 (2020): Revista Técnica "energía", Edición No. 17, ISSUE I
- Jonnathan Morales, William Quitiaquez, Isaac Simbaña, Mathematics optimization models for downstream and midstream petroleum sectors. Literature review and future research directions , Revista Técnica "energía": Vol. 17 No. 1 (2020): Revista Técnica "energía", Edición No. 17, ISSUE I
- Isaac Simbaña, William Quitiaquez, Patricio Cabezas, Patricio Quitiaquez, Comparative study of the efficiency of rectangular and triangular flat plate solar collectors through finite element method , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- William Quitiaquez, Andrés Argüello, Isaac Simbaña, Patricio Quitiaquez, Evaluation of the gasoline engines behavior by the air flow simulation through the throttle body , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- Alex Rivera, William Quitiaquez, Isaac Simbaña, Patricio Quitiaquez, Study of Steam Generation and Distribution in a Hospital to Improve Energy Efficiency Using Thermography, Ultrasound, and Gas Analyzer , Revista Técnica "energía": Vol. 20 No. 2 (2024): Revista Técnica "energía", Edición No. 20, ISSUE II
- Isaac Simbaña, William Quitiaquez, José Estupiñán, Fernando Toapanta-Ramos, Leonidas Ramírez, Performance evaluation of a direct expansion solar-assisted heat pump by numerical simulation of the throttling process in the expansion device , Revista Técnica "energía": Vol. 19 No. 1 (2022): Revista Técnica "energía", Edición No. 19, ISSUE I
- William Quitiaquez, Christian Cholca, Erika Pilataxi, Fernando Toapanta, Evaluation of Flexible Configuration Pipeline Networks for Hydrocarbon Transportation , Revista Técnica "energía": Vol. 20 No. 1 (2023): Revista Técnica "energía", Edición No. 20, ISSUE I
- William Quitiaquez, Jorge Chimarro, John Valarezo, Patricio Quitiaquez, César Melendrez, Fernando Toapanta, Validation of a prototype of three-phase energy meter as support for an energy audit , Revista Técnica "energía": Vol. 17 No. 2 (2021): Revista Técnica "energía", Edición No. 17, ISSUE II
- Kleber Zhañay, Cristian Leiva, Erika Pilataxi, William Quitiaquez, Wear - Sediment Quantity Correlation Model for Preventive Maintenance Scheduling of a Hydroelectric Power Plant , Revista Técnica "energía": Vol. 21 No. 2 (2025): Revista Técnica "energía", Edición No. 21, ISSUE II
This scientific article deals with the study and simulation of a radiator that is based on a cross-flow tubular heat exchanger, which has the purpose of cooling the processor, graphics card of a CPU or various hardware in computer systems. Various simulations are carried out in the ANSYS program having various inlet temperatures ranging from
75 °C to 90 °C and with different mass flows. The results show that, as the inlet temperature of the fluid to be cooled increases, the outlet of this fluid also increases. However, when mass flow is increased there is a decrease in heat rejection in computational devices.
Article visits 1195 | PDF visits 707
Downloads
1] A. Addagatla, J. Fernandes, D. Mani, D. Agonafer, and V. Mulay, “Effect of warm water cooling for an isolated hybrid liquid cooled server,” Annu. IEEE Semicond. Therm. Meas. Manag. Symp., vol. 2015-April, pp. 203–207, 2015, doi: 10.1109/SEMI-THERM.2015.7100161.
[2] K. Nemati, T. Gao, B. T. Murray, and B. Sammakia, “Experimental characterization of the rear door fans and heat exchanger of a fully-enclosed, hybrid-cooled server cabinet,” Annu. IEEE Semicond. Therm. Meas. Manag. Symp., vol. 2015-April, pp. 155–162, 2015, doi: 10.1109/SEMI-THERM.2015.7100154.
[3] M. A. Kadhim, Y. T. Al-Anii, N. Kapur, J. L. Summers, and H. M. Thompson, “Performance of a mixed mode air handling unit for direct liquid-cooled servers,” Annu. IEEE Semicond. Therm. Meas. Manag. Symp., pp. 172–178, 2017, doi: 10.1109/SEMI-THERM.2017.7896926.
[4] S. J. Ovaska, R. E. Dragseth, and S. A. Hanssen, “Impact of retrofitted CPU water cooling on supercomputer performance and power consumption,” Conf. Proc. - IEEE SOUTHEASTCON, vol. 2016-July, pp. 1–2, 2016, doi: 10.1109/SECON.2016.7506669.
[5] N. Raja Kuppusamy and L. Poh Seng, “Study on thermal and hydrodynamic performance of a triple fluid heat exchanger with different passes and rows,” Energy Procedia, vol. 158, pp. 5901–5906, 2019, doi: 10.1016/j.egypro.2019.01.534.
[6] D. P. Kulkarni and R. Steinbrecher, “Compact liquid enhanced air cooling thermal solution for high power processors in existing air-cooled platforms,” Annu. IEEE Semicond. Therm. Meas. Manag. Symp., vol. Part F1214, pp. 81–85, 2016, doi: 10.1109/SEMI-THERM.2016.7458449.
[7] G. Tang, Y. Han, and X. Zhang, Compact heat exchanger design and energy efficiency optimization for data centre cooling application, vol. 2018-Febru. 2018.
[8] Y. Fan, C. Winkel, D. Kulkarni, and W. Tian, “Analytical Design Methodology for Liquid Based Cooling Solution for High TDP CPUs,” Proc. 17th Intersoc. Conf. Therm. Thermomechanical Phenom. Electron. Syst. ITherm 2018, pp. 582–586, 2018, doi: 10.1109/ITHERM.2018.8419562.
[9] T. A. Shedd and R. A. Morell, “Cooling 11.6 TFlops (1500 watts) in an office environment,” Annu. IEEE Semicond. Therm. Meas. Manag. Symp., pp. 122–124, 2017, doi: 10.1109/SEMI-THERM.2017.7896918.
[10] G. R. Wagner et al., “Test results from the comparison of three liquid cooling methods for high-power processors,” Proc. 15th Intersoc. Conf. Therm. Thermomechanical Phenom. Electron. Syst. ITherm 2016, pp. 619–624, 2016, doi: 10.1109/ITHERM.2016.7517605.
[11] A. C. Kheirabadi and D. Groulx, “Cooling of server electronics: A design review of existing technology,” Appl. Therm. Eng., vol. 105, no. 2016, pp. 622–638, 2016, doi: 10.1016/j.applthermaleng.2016.03.056.
[12] S. O. Tan and H. Demirel, “Performance and cooling efficiency of thermoelectric modules on server central processing unit and Northbridge,” Comput. Electr. Eng., vol. 46, pp. 46–55, 2015, doi: 10.1016/j.compeleceng.2015.07.012.
[13] A. C. Kheirabadi and D. Groulx, “Experimental evaluation of a thermal contact liquid cooling system for server electronics,” Appl. Therm. Eng., vol. 129, pp. 1010–1025, 2018, doi: 10.1016/j.applthermaleng.2017.10.098.
[14] W. Wang, L. Chen, Y. Kong, L. Yang, Y. Niu, and X. Du, “Cooling performance evaluation for double-layer configuration of air-cooled heat exchanger,” Int. J. Heat Mass Transf., vol. 151, p. 119396, 2020, doi: 10.1016/j.ijheatmasstransfer.2020.119396.
[15] S. Maalej, A. Zayoud, I. Abdelaziz, I. Saad, and M. C. Zaghdoudi, “Thermal performance of finned heat pipe system for Central Processing Unit cooling,” Energy Convers. Manag., vol. 218, no. February, p. 112977, 2020, doi: 10.1016/j.enconman.2020.112977.
[16] Y. Sun, T. Wang, L. Yang, L. Hu, and X. Zeng, “Research of an integrated cooling system consisted of compression refrigeration and pump-driven heat pipe for data centers,” Energy Build., vol. 187, pp. 16–23, 2019, doi: 10.1016/j.enbuild.2019.01.050.
[17] K. Liang, Z. Li, M. Chen, and H. Jiang, “Comparisons between heat pipe, thermoelectric system, and vapour compression refrigeration system for electronics cooling,” Appl. Therm. Eng., vol. 146, no. September 2018, pp. 260–267, 2019, doi: 10.1016/j.applthermaleng.2018.09.120.
[18] L. Bilurbina Alter, F. Liesa Mestres, and J. I. Iribarren Laco, Corrosión y protección, vol. 53, no. 9. 2003.